Skip to main content

SDH OptiX OSN 7500 II PDH Boards

SDH OptiX OSN 7500 II PDH Boards below:

The PDH boards include the PDH service interface boards and PDH service processing boards, to transmit/receive and process E1/T1 signals, E3/T3 signals, E4/STM-1 electrical signals, and DDN signals.

PQ1 (63xE1 service processing board).
PQM (63xE1/T1 service processing board).
PQ3 (12xE3/T3 service processing board).
DX1 (DDN service accessing and converging board).
SPQ4 (4xE4/STM-1 electrical processing board).
D12B (32xE1/T1 access board).
D12S (32xE1/T1 switching access board).
D75S (32xE1 switching access board).
D34S (6xE3/T3 switching access board).
MU04 (4xE4/STM-1 electrical interface board).
DM12 (DDN service interface board).
TSB8 (8-channel electrical interface protection switching board).

1 Relationship between the feature code of the PQ1 and the type of interface impedance

BoardFeature CodeType of Interface Impedance
SSN2PQ1A01A0175-ohm
SSN2PQ1B01B01120-ohm

2 Functions and features of the PQM

Function and FeaturePQM
Basic functionsProcesses 63xE1/T1 signals.
Service
processing
Transmits/Receives and processes 63xE1/T1 electrical signals
when working with the interface board. Each channel can be
configured as E1 or T1.
Overhead
processing
Supports the processing of the path overheads at the VC-12
level, such as the J2 byte.
Alarms and
performance
events
Reports various alarms and performance events, which
facilitates the management and maintenance of the equipment.
Maintenance
features
Supports inloops and outloops at electrical interfaces.
Supports warm resets and cold resets. The warm reset
does not affect services.
Supports the query of the manufacturing information of the board.
Supports the in-service loading of the FPGA.
Supports the upgrade of the board software without affecting services.
Supports the PRBS function. For details, see Availability.
Supports the CRC function.
Protection
schemes
Supports the TPS protection when working with the interface board.


3.Functions and features of the PQ3


Function and
 Feature
PQ3
Basic functionsProcesses 12xE3/T3 signals.
Service
processing
Transmits/Receives and processes 12xE3/T3 electrical signals.
Supports the E13 function, which is used to converge E1
services into E3 services.
Supports the M13 function, which is used to converge T1
services into T3 services.
Overhead
processing
Supports the setting and query of all the path overhead bytes
at the VC-3 level.
Alarms and
performance
events
Reports various alarms and performance events, which
facilitates the management and maintenance of the equipment.
Maintenance
features
Supports inloops and outloops at electrical interfaces.
Supports warm resets and cold resets. The warm reset
does not affect services.
Supports the query of the manufacturing information of the board.
Supports the in-service loading of the FPGA.
Supports the upgrade of the board software without affecting services.
Supports the PRBS function. For details, see Availability.
Supports the CRC function.
Protection
schemes
Supports the TPS protection when working with the interface
board and the switching and bridging board.


4. Relationship between the feature code of the DX1 and the type of interface impedance

BoardFeature CodeType of Interface Impedance
SSN3DX1A01A0175-ohm
SSN3DX1B01B01120-ohm
5. Functions and features of the SPQ4

Function and
 Feature
SPQ4
Basic functionsProcesses 4xSTM-1/E4 signals.
Service
processing
Transmits/Receives and processes 4xE4/STM-1 electrical
signals. The E4 signals and STM-1 signals are compatible on
each channel. Supports the VC-12 services, VC-3 services,
and VC-4 services.
Overhead
processing
Processes the section overheads of the STM-1 signals,
such as B1, B2, K1, K2, M1, F1, and D1–D12.
Supports the transparent transmission and termination of
 the path overhead bytes including J1, B3, C2, G1, and H4.
Supports the setting and query of the J0, J1, and C2 bytes.
Alarms and
performance
events
Reports various alarms and performance events, which
facilitates the management and maintenance of the equipment.
Maintenance
features
Supports inloops and outloops at optical interfaces.
Supports warm resets and cold resets. The warm reset
does not affect services.
Supports the query of the manufacturing information of the board.
Supports the in-service loading of the FPGA.
Supports the upgrade of the board software without affecting services.
Does not support the CRC function.
Protection
schemes
Supports the TPS protection when working with the interface
board and the switching and bridging board.
Supports the Two-fiber ring MSP.
Supports the Linear MSP.
Supports the SNCP.


6. The D12B is a PDH interface board. The D12B can be used on the OptiX OSN equipment series to transmit and receive signals for the PDH processing board. To transmit/receive and process signals, the interface board must be used with its corresponding processing board.

7. The D12S is a PDH interface switching board. The D12S can be used on the OptiX OSN equipment series to transmit and receive signals for the PDH processing board. In addition, when the corresponding PDH processing board is configured with the TPS protection, the interface switching board is required to perform the TPS protection.

8.The D75S is a PDH interface switching board. The D75S can be used on the OptiX OSN equipment series to transmit and receive signals for the PDH processing board. In addition, when the corresponding PDH processing board is configured with the TPS protection, the interface switching board is required to perform the TPS protection.

9.The D34S is a PDH interface switching board. The D34S can be used on the OptiX OSN equipment series to transmit and receive signals for the PDH processing board. In addition, when the corresponding PDH processing board is configured with the TPS protection, the interface switching board is required to perform the TPS protection.

10. The MU04 is an E4/STM-1 electrical interface board. The MU04 can be used on the OptiX OSN equipment series to transmit and receive signals for the E4/STM-1 electrical processing board.

11.The DM12 is a service interface board. The DM12 can be used on the OptiX OSN equipment series to transmit and receive electrical signals of the DDN, sub-rate, and framed E1services.

12. The TSB8 is used to provide the TPS protection.

The TSB8 can work with the MU04 and D34S to realize the TPS protection on different processing boards.

  • The TSB8 can work with the MU04 to realize the TPS protection on the SPQ4.
  • The TSB8 can work with the D34S to realize the TPS protection on the PQ3.
  • The TSB8 can work with the ETS8 to realize the TPS protection on the EFS0A.

Above are functions and features of OptiX OSN 7500 II PDH Boards .

Comments

Popular posts from this blog

Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell

Hong Telecom Equipment Service LTD (HongTelecom) focus on Huawei/Ericsson/Nokia/ZTE wireless spare parts, we sell 2G/3G/4G RRU BBU and core network spare parts. Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell 02311VMD RRU5501 RRU5501-WD5MZAAPHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*60W) 02312BSJ RRU5502 RRU5502-WD5MZAAPIAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*80W) 02312DDF RRU5502 RRU5502-WD5MZAAPIAZD-WUYI(TX1830-1880MHz/RX1735-1785MHz, TX2110-2165MHz/RX1920-1975MHz,-48VDC,9.8G,4T4R*2,4*80W) 02311SNY RRU5507 RRU5507-WD5MZAANHBKD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02311RHP RRU5507c RRU5507c-WD5MZAANHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02312BRX RRU5508 RRU5508-WD5MZAANHAAC-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110

Data sheet of ZTE F600W Technical Specification

Hong Telecom is able to provide ZTE ONT F600W. ZTE ZXHN F600W is a GPON Optical Network Terminal designed for FTTH scenario. It provides video (IPTV), high speed internet access and Wi-Fi for home network connection. It has a small, smart appearance and green, energy-saving advantage. GPON Interface: Optical port : 1 x GPON interface (SC/APC); Transmission Distance: 0 ~ 20km; Transmit rate: 2.488Gbps downstream; 1.244Gbps upstream; User Network Interface * 4 x 10/100/1000Base-T; Half/full duplex; Auto MDI/MDIX; Auto negotiation * 1 x Wi-Fi interface: IEEE 802.11b/g/n @2.4G Hz * 1 x USB host interface Optical Module: * Wavelength:   Receiving:1480~1500 nm   Transmitting: 1290~1330 nm * Receiving Sensitivity: -28dBm * Transmitting Optical Power: 0.5~5dBm. Physical Performance ZTE ZXHN F600W ONT : * Power consumption: <8W * Dimensions: 220mm(W) x 44mm(H) x 160mm(D) * Working temperature: 0 o C ~ 40 o C * Working humidity: 5% ~ 95% * Weight: about 300g * Power

Huawei RRU5901 RRU5901w RRU5902 RRU5903 RRU5904 RRU5905 RRU3989 for sell

Hong Telecom Equipment Service LTD (HongTelecom) focus on Huawei/Ericsson/Nokia/ZTE wireless spare parts, we sell 2G/3G/4G RRU BBU and core network spare parts. Huawei RRU5901 RRU5901w RRU5902 RRU5903 RRU5904 RRU5905 RRU3989 for sell 02311QMD RRU5901 RRU5901,WD5MERUMG30,WUYI(TX1805-1880MHz/RX1710-1785MHz,-48VDC,9.8G,4T4R,4*40W) 02312AAR RRU5901w RRU5901w-WD5MERUMG30W-WUYI(TX1805-1880MHz/RX1710-1785MHz,-48VDC,9.8G,4T4R,4*40W) 02312BTR RRU5902 RRU5902-WD5MJRULC8BA-WUYI(TX935-960MHz/RX890-915MHz,-48VDC,9.8G,2T4R,2*60W) 02312BTS RRU5903 RRU5903-WD5MJRULG8BB-WUYI(TX935-960MHz/RX890-915MHz,-48VDC,9.8G,2T4R,2*80W) 02311UWH RRU5904 RRU5904-WD5MERUMH30-WUYI(TX1805-1880MHz/RX1710-1785MHz,-48VDC,9.8G,4T4R,4*60W) 02311UWT RRU5904 RRU5904-WD5MWRUMH10-WUYI(TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R,4*60W) 02311PRD RRU5905 RRU5905-WD5MERULG31-WUYI(TX1805-1880MHz/RX1710-1785MHz,-48VDC,9.8G,2T2R,2*80W) 02311YAJ RRU5905 RRU5905-WD5MERULH3D-WUYI(TX180