 1 Overall structure of a controller enclosure

1System enclosure2BBU module
3Controller4Power module
5Management module6Interface module

2 Front view of a controller enclosure
1BBU module2BBU module latch
3BBU module latch4Controller panel latch
5Information plate (with ESN)6Power indicator/Power button
7Controller8Controller latch
9Controller handle

NOTE:
 *  After opening the controller panel latch, you will see that each controller contains three fan modules.
 *  BBU slots are numbered from left to right. BBUs of 5600 V3 are inserted into slots 0 and 3, and those of 5800 V3 are inserted into slots 0, 1, and 3. The other slots are vacant (filler panels are installed for these slots).
 *  The information plate records device information.


3 Rear view of a controller enclosure

1Power module handle2Power module
3Power module socket4Management module
5Management network port6Maintenance network port
The management network port is used to
connect to the maintenance terminal.
The maintenance network port is designed
for special maintenance in emergency.
7Serial port8Management module handle
The serial port is used to connect to the
maintenance terminal.
9USB port10GE electrical port
Reserved functionThe GE electrical port is used to connect to
 the GE electrical port of the application server.
1110 Gbit/s TOE port1210 Gbit/s FCoE port
The 10 Gbit/s TOE port is used to connect
to the 10 Gbit/s TOE port of the application server.
The 10 Gbit/s FCoE port is used to connect
 to the 10 Gbit/s FCoE port of the application server.
1316 Gbit/s Fibre Channel port148 Gbit/s Fibre Channel port
The 16 Gbit/s Fibre Channel port is used to
connect to the 16 Gbit/s Fibre Channel port
of the application server.
The 8 Gbit/s Fibre Channel port is used to
connect to the 8 Gbit/s Fibre Channel port
 of the application server.
15Mini SAS HD expansion port
The mini SAS HD expansion port is used to
connect to the disk enclosure.

The slots for interface modules of a 3 U controller enclosure are B0, B1, B2, B3, B4, B5, B6, B7, A7, A6, A5, A4, A3, A2, A1, and A0 from left to right. Among the slots, A0 to A7 are slots for the interface modules of controller A and B0 to B7 are slots for the interface modules of controller B.


NOTE:
A controller enclosure provides the following interface modules. You can configure them based on service needs.
 *  Slots A0 and B0 accommodate back-end ports and only allow 12 Gbit/s SAS expansion modules.
 *  A6, A7, B6, and B7 are slots for front-end interface modules and do not support 12 Gbit/s SAS expansion modules.
 *  When the storage device requires IP Scale-out, SmartIO interface modules must be installed in A3 and B3 slots for the IP Scale-out.
 *  Management module (mandatory): used for management and maintenance
 *  12 Gbit/s SAS expansion module (mandatory): used for connecting disk enclosures
 *  Interface modules (optional but at least one type required): used for connecting application servers
 *  When the maintenance network port is used for management and maintenance, the maintenance network port can only be used by Huawei technical support for emergency maintenance and cannot be connected to the same network with the management network port. Otherwise, a network loopback may occur, causing a network storm. The initial value for the IP address of the maintenance network port is 172.31.128.101 or 172.31.128.102. The default subnet mask is 255.255.0.0. You are advised to only connect the management network port to the network.



Below OceanStor 5600 V3 accessories can provide by Hong Telecom Equipment Service Ltd :

5600V3-64G-AC 02350BSB 5600V3-64G-AC : 5600 V3 (3U, dual control, AC, 64GB, SPE62C0300)
5600V3-128G-AC 02359805 5600V3-128G-AC : 5600 V3 (3U, dual control, AC, 128GB, SPE62C0300)
LIC-5600V3-VIR 88032KNM LIC-5600V3-VIR : Intelligent heterogeneous virtualization licensing
LIC-5600V3-SNAP 88032KNN LIC-5600V3-SNAP : Snapshot license
LIC-5600V3-COPY 88032KNP LIC-5600V3-COPY : LUN copy license
LIC-5600V3-CLON 88032KNQ LIC-5600V3-CLON : Cloning license
LIC-5600V3-REP 88032KNR LIC-5600V3-REP : Remote Copy Licenses
LIC-5600V3-TIER 88032KNT LIC-5600V3-TIER : Intelligent data classification
LIC-5600V3-QOS 88032KNV LIC-5600V3-QOS : Intelligent Service Quality Control
LIC-5600V3-PAR 88032KNW LIC-5600V3-PAR : Intelligent cache partition
LIC-5600V3-PATH 88032KNY LIC-5600V3-PATH : OceanStor Huawei multi-path software license
LIC-5600V3-BR 88032LHE LIC-5600V3-BR : System Reporting Software License
LIC-5600V3-BS 88032NMP LIC-5600V3-BS : Block Foundation Package Authorization (including Device Management, SmartThin, SmartMulti-tenant, SmartMigration, SmartErase, SmartMotion, Cloud Service)
LIC-5600V3-MIR 88032QAN LIC-5600V3-MIR : Volume mirroring license
LIC-5600V3-CACH 88032RFV LIC-5600V3-CACH : Smart SSD cache
LIC-5600V3-WORM 88032RFW LIC-5600V3-WORM : WORM license
LIC-5600V3-CD 88032RFX LIC-5600V3-CD : Smart Data Compression (for LUNs)
LIC-56-UPGRADE 88032UCV LIC-56-UPGRADE : Block Storage Upgrade Unified Storage Foundation Package Authorization with SmartDedupe & SmartCompression (for FS), SmartQuota, NFS, CIFS, NDMP)
LIC-56-HYPERPAK 88032UDB LIC-56-HYPERPAK : Data Protection Software Suite Licensing (including HyperSnap, HyperCopy, HyperClone, HyperMirror)
LIC-56-SMARTPAK 88032UDF LIC-56-SMARTPAK : Efficiency Enhancement Software Suite License (with SmartTier, SmartCache)
LIC-56V3-METRO 88032WXK LIC-56V3-METRO : Array Dual Live License
LIC-56V3-VAULT 88032XLY LIC-56V3-VAULT : Integrated backup license
LIC-56V3-ACCPAK 88033NGB LIC-56V3-ACCPAK : Performance Accelerator Suite licenses (including SmartTier, SmartCache, SmartQos, SmartPartition)
LIC-56V3-DRPAK 88033NGC LIC-56V3-DRPAK : Disaster Recovery Solution Suite License (including HyperSnap, HyperReplication)
LIC-56V3-METPAK 88033NGD LIC-56V3-METPAK : Dual Live Solution Suite License (including HyperMetro, HyperSnap)
LIC-56V3-VIRPAK 88033NGE LIC-56V3-VIRPAK : Consolidated Migration Solution Suite Licenses (including 2 * SmartVirtualization, HyperMirror, SmartMigration)






Comments

Popular posts from this blog

Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell

Hong Telecom Equipment Service LTD (HongTelecom) focus on Huawei/Ericsson/Nokia/ZTE wireless spare parts, we sell 2G/3G/4G RRU BBU and core network spare parts. Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell 02311VMD RRU5501 RRU5501-WD5MZAAPHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*60W) 02312BSJ RRU5502 RRU5502-WD5MZAAPIAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*80W) 02312DDF RRU5502 RRU5502-WD5MZAAPIAZD-WUYI(TX1830-1880MHz/RX1735-1785MHz, TX2110-2165MHz/RX1920-1975MHz,-48VDC,9.8G,4T4R*2,4*80W) 02311SNY RRU5507 RRU5507-WD5MZAANHBKD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02311RHP RRU5507c RRU5507c-WD5MZAANHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02312BRX RRU5508 RRU5508-WD5MZAANHAAC-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110

Data sheet of ZTE F600W Technical Specification

Hong Telecom is able to provide ZTE ONT F600W. ZTE ZXHN F600W is a GPON Optical Network Terminal designed for FTTH scenario. It provides video (IPTV), high speed internet access and Wi-Fi for home network connection. It has a small, smart appearance and green, energy-saving advantage. GPON Interface: Optical port : 1 x GPON interface (SC/APC); Transmission Distance: 0 ~ 20km; Transmit rate: 2.488Gbps downstream; 1.244Gbps upstream; User Network Interface * 4 x 10/100/1000Base-T; Half/full duplex; Auto MDI/MDIX; Auto negotiation * 1 x Wi-Fi interface: IEEE 802.11b/g/n @2.4G Hz * 1 x USB host interface Optical Module: * Wavelength:   Receiving:1480~1500 nm   Transmitting: 1290~1330 nm * Receiving Sensitivity: -28dBm * Transmitting Optical Power: 0.5~5dBm. Physical Performance ZTE ZXHN F600W ONT : * Power consumption: <8W * Dimensions: 220mm(W) x 44mm(H) x 160mm(D) * Working temperature: 0 o C ~ 40 o C * Working humidity: 5% ~ 95% * Weight: about 300g * Power

Huawei OptiX RTN 900 series IP microwave systems ODU details

Huawei OptiX RTN 900 series IP microwave systems Build faster, more-reliable radio transmission links supporting multiple services 1) Ultra-large bandwidth — Utilizing high modulation schemes, cross-polarization interference cancellation, and Ethernet frame header compression technologies; offer 2 Gbit/s capacity per channel 2) Carrier-grade reliability — Protection and redundancy at the network, link, and equipment levels; Ingress Protection (IP65) for water and dust, and 8 kA surge protection for high-availability operation in harsh environments 3) Easy maintenance — Unified NMS with Optics and Routers for seamless end-to-end networking, supports TP-Assist features for flexible and cost-effective O&M 4) Enhanced security – Support AES 128/256 air link encryption and device anti-theft functions Features as below : The ODU is the outdoor unit for the OptiX RTN 900. It converts frequencies and amplifies signals. The OptiX RTN 900 product series can