The OptiX OSN 8800 supports 40 Gbit/s and 100 Gbit/s line rates and a 6.4 Tbit/s cross-connect capacity. It features power saving, and high reliability and maintainability. In this article, HongTelecom will introduce Huawei OptiX OSN 8800 T64 cross-connection function.
As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.
For related articles, visit the HongTelecom Blog and HongTelecom Blogger.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.
Highest Cross-Connect Capacity with Flexible Large-Capacity Service Grooming
- Features high cross-connect capacity. A single subrack supports a maximum of 6.4 Tbit/s cross-connect capacity, implementing large-capacity service grooming. Only one subrack is required for the large-capacity service grooming and therefore lowers power consumption and reduces the floor space.
- Supports multi-granularity OTN cross-connection, that is, ODUk cross-connection, where k can be 0, 1, 2, 2e, 3, 4, or flex.
- Supports encapsulation of VC, ODUk, and packet services by using universal line boards and unified switching of VC, ODUk, and packet services by using cross-connect boards, which achieves converged service grooming planes and flexible bandwidth allocation.
Cross-Connect Capacities
The cross-connect capacity of a slot in an OptiX OSN 8800 T64 subrack vary according to the type of cross-connect board installed in the slot.
OptiX OSN 8800 T64 subracks can cross-connect ODU0, ODU1, ODU2, ODU2e, ODU3, ODU4, ODUflex, VC-4, VC-3, and VC-12 granularities at the same time. Slots IU1-IU8, IU11-IU42, and IU45-IU68 provide the same cross-connect capacity. As shown in Table 1.
Subrack Type | Cross-Connect Board | Maximum Cross-Connect Capacity of Each Slota | Maximum Cross-Connect Capacity of Subrack | ||||
---|---|---|---|---|---|---|---|
ODUkb | VC-4 | VC-3/VC-12e | ODUkb | VC-4 | VC-3/VC-12 | ||
Enhanced | USXH | N/A | 20 Gbit/s | N/A | N/A | 1.28 Tbit/s | N/A |
Enhanced | USXH+UXCTc | 100 Gbit/s | 20 Gbit/s | N/A | 6.4 Tbit/s | 1.28 Tbit/s | N/A |
Enhanced | SXH | N/A | 20 Gbit/s | N/A | N/A | 1.28 Tbit/s | N/A |
Enhanced | SXM | N/A | 20 Gbit/s | 20 Gbit/s | N/A | 1.28 Tbit/s | 80 Gbit/s |
Enhanced | SXH+XCTc | 40 Gbit/s | 20 Gbit/s | N/A | 2.56 Tbit/s | 1.28 Tbit/s | N/A |
Enhanced | SXM+XCTc | 40 Gbit/s | 20 Gbit/s | 20 Gbit/s | 2.56 Tbit/s | 1.28 Tbit/s | 80 Gbit/s |
General | SXH | N/A | 20 Gbit/s | N/A | N/A | 1.28 Tbit/s | N/A |
General | SXM | N/A | 20 Gbit/s | 20 Gbit/s | N/A | 1.28 Tbit/s | 80 Gbit/s |
General | SXH+XCTd | 40 Gbit/s | 20 Gbit/s | N/A | 2.56 Tbit/s | 1.28 Tbit/s | N/A |
General | SXM+XCTd | 40 Gbit/s | 20 Gbit/s | 20 Gbit/s | 2.56 Tbit/s | 1.28 Tbit/s | 80 Gbit/s |
a: In OptiX OSN 8800 T64 enhanced subrack, the maximum OTN service cross-connect capacity of a single slot can be smoothly increased from 40 Gbit/s to 100 Gbit/s by replacing the cross-connect board. b: k=0, 1, 2, 2e, 3, 4 or flex. Only the USXH+UXCT supports ODU4 granularities. c: Enhanced OptiX OSN 8800 T64 subracks must be configured with both the USXH and UXCT boards, the SXH and XCT boards or the SXM and XCT boards to cross-connect ODUk granularities. d: General OptiX OSN 8800 T64 subracks must be configured with both the SXH and XCT boards or the SXM and XCT boards to cross-connect ODUk granularities. e: All service slots share a bandwidth of 80 Gbit/s. Two functional versions are available for SXH, SXM, and XCT boards: TNK2 and TNK4. The boards can be used in OptiX OSN 8800 T64 enhanced subrack only when they are of the TNK4 version. |
Cross-Connect Board Redundancy
Two cross-connect boards can be configured for 1+1 backup.
The active and standby cross-connect boards in a subrack connect to all other boards through the backplane bus to protect cross-connection services. For details, see Figure 1, Figure 2, and Figure 3 .Product | Cross-connect Board Supported |
---|---|
Enhanced OptiX OSN 8800 T64 | SXM+XCT, SXH+XCT, or USXH+UXCT |
General OptiX OSN 8800 T64 | SXM+XCT or SXH+XCT |
Enhanced OptiX OSN 8800 T32 | XCM, XCH, UXCM, or UXCH |
General OptiX OSN 8800 T32 | XCH or XCM |
OptiX OSN 8800 T16 | XCH or UXCMa |
When the standby cross-connect board detects that the active cross-connect board is faulty or receives a switching command from the NMS, it immediately takes over the active cross-connect board, sets itself as the active cross-connect board, and reports a switching event. Services on the subrack are not affected during the switching.
There are two types of switching for the 1+1 protection switching of cross-connect boards:
NOTE:
Active/Standby switching of cross-connect boards usually has no impact on services. For the TN54EX2, TN54EG16, and TN54PND2 boards, however, active/standby switching on the boards will cause transient interruption of services on the board.
- Automatic switching
The cross-connect board detects its own status through hardware or software. If it is in the abnormal status, a switching is performed automatically. The switching is performed by the board and no manual operation is required.
Switching trigger conditions are as follows:- A hardware fault occurs on the cross-connect board.
- The cross-connect board goes offline when, for example, it is removed or undergoes a cold reset.
- A fault occurs on bus between a service board and the cross-connect board.
- Switching occurs between the active and standby STG boards in an OptiX OSN 8800 T64/T32 subrack.
- Manual switching
When a switching is required in a test during the normal running of the active and the standby SCCs, the switching can be performed manually.
NOTE:
The letter k in "ODUk" is 0, 1, 2, 3,4, or flex.
The letter n in "VC-n" is 12, 3, or 4.
The SXM board supports VC-4/VC-3/VC-12 signals. The SXH/USXH board supports VC-4 signals.
NOTE:
The letter k in "ODUk" is 0, 1, 2, 3,4, or flex.
The letter n in "VC-n" is 12, 3, or 4.
Only UXCH/UXCM board supports packet services.
The XCM/UXCM board supports VC-4/VC-3/VC-12 signals. The XCH/UXCH board supports VC-4 signals.
The letter n in "VC-n" is 12, 3, or 4.
Only UXCH/UXCM board supports packet services.
The XCM/UXCM board supports VC-4/VC-3/VC-12 signals. The XCH/UXCH board supports VC-4 signals.
NOTE:
The letter k in "ODUk" is 0, 1, 2, 3, flex, or 4.
The letter n in "VC-n" is 12, 3, or 4.
Only UXCM board supports packet services.
Only UXCM board supports VC-4/VC-3/VC-12 signals.
Related main control board list
TN16XCH
|
High Cross-connection, System Control and Clock Processing Board
|
TNK2SXM
|
OptiX OSN 8800 T64 centralized cross connect board
|
TNK4SXM
| |
TN52UXCH
|
3.2T Universal Cross Connect Board
|
TN52XCH
|
OptiX OSN 8800 T32 centralized cross connect board
|
TN52UXCM
|
3.2T Universal Cross Connect Board
|
TN52XCM
|
Cross & connect process board (Support high- cross and low-cross)
|
TNK2UXCT
|
6.4T Universal Cross Connect Board
|
TNK2XCT
|
OptiX OSN 8800 T64 centralized cross connect board
|
TNK4XCT
| |
TN16UXCM
|
1.6T Universal Cross Connect, System Control and Clock Processing Board
|
TNK2USXH
|
6.4T Universal Cross Connect Board
|
TNK2SXH
|
OptiX OSN 8800 T64 centralized cross connect board
|
TNK4SXH
|
For related articles, visit the HongTelecom Blog and HongTelecom Blogger.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.
Comments
Post a Comment