Version Mapping

Table 1 lists the mapping between the S6720-30C-EI-24S-AC chassis and software versions.
Table 1 Version mapping
SeriesModelSoftware Version
S6720-EIS6720-30C-EI-24S-AC
V200R008C00 and later versions

Appearance and Structure

 S6720-30C-EI-24S-AC appearance
Similar products: S6720-54C-EI-48S-AC
S5720S-SI
S5720S-52P-SI-AC
S5720S-28X-SI-AC
S5720S-28X-SI-DC
S5720S-52X-SI-AC
S5720S-52X-SI-DC
1Twenty-four 10GE SFP+ ports
Applicable modules and cables:
  • GE optical module
  • GE-CWDM optical module
  • GE-DWDM optical module
  • GE copper module (100M/1000M auto-sensing supported in V200R009 and later versions)
  • 10GE SFP+ optical module (OSXD22N00 not supported)
  • 10GE-CWDM optical module
  • 10GE-DWDM optical module (applicable in V200R009C00 and later versions)
  • 1 m, 3 m, 5 m, and 10 m SFP+ high-speed copper cables
  • 3 m and 10 m SFP+ AOC cables
  • 0.5 m and 1.5 m SFP+ dedicated stack copper cables (the last 16 ports are supported, used for zero-configuration stacking, supported in V200R011C10 and later versions)
2Two 40GE QSFP+ ports
Applicable modules and cables:
  • QSFP+ optical module
  • 1 m, 3 m, and 5 m QSFP+ to QSFP+ high-speed copper cables
  • 1 m, 3 m, and 5 m QSFP+ to 4*SFP+ high-speed copper cables
  • 10 m QSFP+ to QSFP+ AOC cable (applicable in V200R009C00 and later versions)
  • 10 m QSFP+ to 4*SFP+ AOC cable (applicable in V200R009C00 and later versions)
NOTE:
A 40GE QSFP+ optical port can be split into four 10GE ports.
3ETH management port4One console port
5One USB port6Ground screw
NOTE:
It is used with a ground cable.
7ESN label
NOTE:
You can draw it out to view the ESN and MAC address of the switch.
8Rear card slot
NOTE:
Card supported: ES5D21Q04Q01 (4-Port 40 Gig QSFP+ Rear Interface Card)
9Fan slot
NOTE:
Applicable fan module: FAN-060B-B Fan Module
10Power module slot 2
NOTE:
Applicable power modules:
  • 350 W DC power module
  • 600 W AC power module
11Power module slot 1
NOTE:
Applicable power modules:
  • 350 W DC power module
  • 600 W AC power module
--

Port Description

10GE SFP+ port
A 10GE SFP+ Ethernet optical port supports auto-sensing to 1000 Mbit/s. It sends and receives service data at 1000 Mbit/s or 10 Gbit/s. Table 2 describes the attributes of a 10GE SFP+ Ethernet optical port.
Table 2 Attributes of a 10GE SFP+ port
AttributeDescription
Connector typeLC/PC
Optical port attributesDepend on the optical module used
Standards complianceIEEE802.3ae
Working modeGE/10GE auto-sensing
40GE QSFP+ port
A 40GE QSFP+ optical port sends and receives service traffic at 40 Gbit/s and can be split into four 10GE ports. After a split, 40GE QSFP+ optical port needs to be connected to a remote device using a 1-to-4 QSFP+ fiber (with matching optical modules), 1-to-4 QSFP+ AOC cable, or a 1-to-4 QSFP+ copper cable. Table 3 describes the attributes of a 40GE QSFP+ optical port.
Table 3 Attributes of a 40GE QSFP+ optical port
AttributeDescription
Connector typeMPO/LC
Optical port attributesDepend on the optical module used
Standards complianceIEEE802.3ba
Console port
The console port is connected to a console for on-site configuration. The port must use a console cable. The console port is used when a switch is powered on for the first time. For details about the attributes of a console port, see Table 4.
Table 4 Attributes of a console port
AttributeDescription
Connector typeRJ45
Standards complianceRS-232
Working modeDuplex Universal Asynchronous Receiver/Transmitter (UART)
Baud rate9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, or 115200 bit/s
Default value: 9600 bit/s
ETH management port
You can connect a switch to a configuration terminal or network management workstation through the ETH management port to configure the switch locally or remotely. The port must use an Ethernet cable. You can choose to download the software package through the ETH management port in the BootLoad menu. File transfer through the ETH management port is faster than transfer through the console port. For details on how to use the ETH management port, see the Configuration Guide - Basic Configurations. Table 5 describes the attributes of an ETH management port.
Table 5 Attributes of an ETH management port
AttributeDescription
Connector typeRJ45
Standards complianceIEEE802.3
Working mode10/100 Mbit/s auto-sensing
Maximum transmission distance100 m
USB port
The USB port can have a USB flash drive connected to upgrade the switch, or transfer configuration files or other files. The USB port can only connect to a USB flash drive that complies with USB 2.0.
 NOTE:
USB flash drives from different vendors differ in model compatibility and drivers. If a USB flash drive cannot be used, try to replace it with another one from a mainstream vendor. Switches support a maximum of 128 GB USB flash drives.

Indicator Description

 NOTE:
Hold down the mode switch button for 6s and release it to start the web initial login mode. Either of the following situations will occur:
  • If the switch has no configuration file, the system attempts to enter the web initial login mode. In this mode, the status of mode indicators is as follows:
    • If the system enters the web initial login mode successfully, all mode indicators turn green and stay on for a maximum of 10 minutes.
    • If the system fails to enter the initial login mode, all mode indicators fast blink for 10 seconds and then restore to the default status.
  • If the switch has a configuration file, the system cannot enter the web initial login mode. In this case, all mode indicators fast blink for 10s, and then return to the default states.
Figure 2 Indicators on the S6720-30C-EI-24S-AC
 NOTE:
The S6720-EI series switches provide a command for setting fault indicators, which help field maintenance personnel find a faulty switch quickly.
The SYS indicator and mode indicators (STAT, SPED, and STCK) are used as fault indicators. When an S6720-EI switch is faulty, you can run the command to turn on the fault indicators. Then the SYS indicator and mode indicators fast blink red to help field maintenance personnel quickly find the faulty switch.
Table 6 Description of indicators on the switch
No.IndicatorNameColorStatusDescription
1PWR1Power module indicator-OffNo power module is available in power module slot 1, or the switch has only one power module but the power module does not work normally.
GreenSteady onA power module is installed in power module slot 1 and is working normally.
YellowSteady onThe switch has two power modules installed. Any of the following situations occurs in power module slot 1:
  • A power module is available in this slot but its power switch is in the OFF position.
  • A power module is available in this slot but it is not connected to a power source.
  • The power module in this slot has failed.
2PWR2Power module indicator-OffNo power module is available in power module slot 2, or the switch has only one power module but the power module does not work normally.
GreenSteady onA power module is installed in power module slot 2 and is working normally.
YellowSteady onThe switch has two power modules installed. Any of the following situations occurs in power module slot 2:
  • A power module is available in this slot but its power switch is in the OFF position.
  • A power module is available in this slot but it is not connected to a power source.
  • The power module in this slot has failed.
3SYSSystem status indicator-OffThe system is not running.
GreenFast blinkingThe system is starting.
GreenSlow blinkingThe system is running normally.
RedSteady onThe system does not work normally after registration, or a fan alarm or temperature alarm has been generated.
4STATStatus indicator-OffThe status mode is not selected.
GreenSteady onThe status mode (default mode) is selected. If the status mode is selected, the service port indicator shows the port link or activity state.
5SPEDSpeed indicator-OffThe speed mode is not selected.
GreenSteady onThe service port indicators show the port speeds. After 45 seconds, the service port indicators automatically restore to the status mode.
6STCKStack indicator-Off
  • If you are not changing the indicator mode (default): The switch is in stack standby or slave state or the stacking function is not enabled on the switch.
  • If you are changing the indicator mode: The stack mode is not selected.
GreenSteady onThe switch is a standby or slave switch in a stack, and the service port indicators show the stack ID of the switch.
GreenBlinking
  • If you are not changing the indicator mode (default): The switch is a stack master switch or a standalone switch with the stacking function enabled.
  • If you are changing the indicator mode: The switch is the master switch in a stack or a standalone switch, and the service port indicators show the stack ID of the master switch.
After 45 seconds, the service port indicators automatically restore to the status mode.
7MODEMode switch button--
  • When you press this button once, the service port indicators change to the speed mode and show the speed of each service port
  • When you press this button a second time, the service port indicators change to the stack mode and show the stack ID of the local switch.
  • When you press this button a third time, the service port indicators restore to the default mode, and the STAT indicator turns green.
If you do not press the MODE button within 45 seconds, the service port indicators restore to the default mode. In this case, the STAT indicator is steady green, the SPED indicator is off, and the STCK indicator is off or blinking green.
8-10GE service port indicator (two indicators for each port)Meanings of service port indicators vary in different modes. For details, see Table 7.
9-40GE service port indicator (one indicator for each port)Meanings of service port indicators vary in different modes. For details, see Table 8.
10-ETH port indicator-OffThe ETH port is not connected.
GreenSteady onThe ETH port is connected.
GreenBlinkingThe ETH port is sending or receiving data.
11-USB-based deployment indicator-Off
  • No USB flash drive is connected to the switch.
  • The USB port is damaged.
  • The indicator is damaged.
  • The USB flash drive does not have any configuration file and cannot be used for deployment.
  • The switch has been upgraded using the USB flash drive and is restarting.
GreenSteady onA USB-based deployment has been completed.
GreenBlinkingThe system is reading data from the USB flash drive.
YellowSteady onThe switch has copied all the required files and completed the file check. The USB flash drive can be removed from the switch.
RedBlinkingAn error has occurred when the system is executing the configuration file or reading data from the USB flash drive.
Table 7 Description of 10GE service port indicators in different modes (two indicators for each port)
Display ModeColorStatusDescription
Status-OffThe port is not connected or has been shut down.
GreenSteady onA link has been established on the port.
YellowBlinkingThe port is sending or receiving data.
Speed-OffThe port is not connected or has been shut down.
Green and yellowSteady on1000M/10GE port: The port is operating at 1000 Mbit/s.
Green and yellowBlinking1000M/10GE port: The port is operating at 10 Gbit/s.
Stack-OffPort indicators do not show the stack ID of the switch.
Green and yellowSteady on
The switch is not the master switch in a stack.
  • If the indicator of a port is steady on, the number of this port is the stack ID of the switch.
  • If the first nine port indicators are steady on, the stack ID of the switch is 0.
Green and yellowBlinking
The switch is the master switch in a stack.
  • If the indicator of a port is blinking, the number of this port is the stack ID of the switch.
  • If the first nine port indicators are blinking, the stack ID of the switch is 0.
Table 8 Description of 40GE service port indicators in different modes (one indicator for each port)
Display ModeColorStatusDescription
Status-OffThe port is not connected or has been shut down.
GreenSteady onA link has been established on the port.
GreenBlinkingThe port is sending or receiving data.
Speed-OffThe port is not connected or has been shut down.
GreenSteady onThe port is operating at 10 Gbit/s.
GreenBlinkingThe port is operating at 40 Gbit/s.

Power Supply Configuration

The S6720-30C-EI-24S-AC can be configured with a single power module or double power modules for 1+1 power redundancy. AC and DC power modules can be used together in the same switch.
Figure 3 shows the power supply connections of dual DC power modules. After DC power is transmitted to the PWR module, the PWR module provides 12 V output voltage, and the motherboard provides power for the entire device.
Figure 3 Power supply connections of dual DC power modules

NEG: negative cableRTN: positive cableGND: 12 V reference ground
Figure 4 shows the power supply connections of dual non-PoE AC power modules. After AC power is transmitted to the PWR module, the PWR module provides 12 V output voltage, and the motherboard provides power for the entire device.
Figure 4 Power supply connections of dual non-PoE AC power modules

L: Live wireN: Neutral wirePGND: Protective ground cableGND: 12 V reference ground

Heat Dissipation

The S6720-30C-EI-24S-AC uses pluggable fan modules for forced air cooling. Air flows in from the left side, right side, and front panel, and exhausts from the rear panel.
 NOTE:
This figure only shows the airflow direction and does not depict the actual device.

Technical Specifications

Table 9 lists technical specifications of the S6720-30C-EI-24S-AC.
Table 9 Technical specifications
ItemDescription
Memory (RAM)2 GB
Flash240 MB
Mean time between failures (MTBF)80.60 years when no interface card is configured; 70.79 years when a 4-port 40GE interface card is configured
Mean time to repair (MTTR)2 hours
Availability> 0.99999
Service port surge protectionNA
Power supply surge protection
  • Using AC power modules: ±6 kV in differential mode, ±6 kV in common mode
  • Using DC power modules: ±1 kV in differential mode, ±2 kV in common mode
Dimensions (W x D x H)442.0 mm x 420.0 mm x 44.4 mm (17.4 in. x 16.5 in. x 1.74 in.)
Weight (including packaging materials)9.8 kg (21.61 lb)
Stack ports
  • Any 10GE SFP+ ports (a maximum of 16 physical ports)
  • Any 40GE QSFP+ ports (a maximum of 6 physical ports)
RTCSupported
RPSNot supported
PoENot supported
Rated voltage range100 V AC to 240 V AC, 50/60 Hz
-48 V DC to -60 V DC
Maximum voltage range90 V AC to 264 V AC, 47 Hz to 63 Hz
-38.4 V DC to -72 V DC
Maximum power consumption (100% throughput, full speed of fans)233.7 W
Typical power consumption (30% of traffic load, tested according to ATIS standard)
  • 147 W (without card)
  • 166 W (with card)
Operating temperature0°C to 45°C (32°F to 113°F) at an altitude of 0-1800 m (0-5906 ft.)
NOTE:
When the altitude is 1800-5000 m (5906-16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).
Storage temperature-40°C to +70°C (-40°F to +158°F)
Noise under normal temperature (27°C, sound power)< 72.1 dBA
Relative humidity5% to 95%, noncondensing
Operating altitude0-5000 m (0-16404 ft.)
Certification
  • EMC certification
  • Safety certification
  • Manufacturing certification
Part number02350DMN

About Us

As a world leading Huawei networking products supplier, Hong Telecom Equipment Service LTD(HongTelecom) keeps regular stock of Huawei router and switch and all cards at very good price, also HongTelecom ship to worldwide with very fast delivery.
For related articles, visit the HongTelecom Blog and HongTelecom Blogger.
For real pictures of related product, visit the HongTelecom Gallery.
To buy related product, visit the HongTelecom Online Shop.

Comments

Popular posts from this blog

Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell

Hong Telecom Equipment Service LTD (HongTelecom) focus on Huawei/Ericsson/Nokia/ZTE wireless spare parts, we sell 2G/3G/4G RRU BBU and core network spare parts. Huawei RRU5501 RRU5502 RRU5507 RRU5507c RRU5508 RRU5702 for sell 02311VMD RRU5501 RRU5501-WD5MZAAPHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*60W) 02312BSJ RRU5502 RRU5502-WD5MZAAPIAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,4T4R*2,4*80W) 02312DDF RRU5502 RRU5502-WD5MZAAPIAZD-WUYI(TX1830-1880MHz/RX1735-1785MHz, TX2110-2165MHz/RX1920-1975MHz,-48VDC,9.8G,4T4R*2,4*80W) 02311SNY RRU5507 RRU5507-WD5MZAANHBKD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02311RHP RRU5507c RRU5507c-WD5MZAANHAAD-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110-2170MHz/RX1920-1980MHz,-48VDC,9.8G,2T4R*2,2*100W) 02312BRX RRU5508 RRU5508-WD5MZAANHAAC-WUYI(TX1805-1880MHz/RX1710-1785MHz, TX2110...

ZTE GPON ONU F821 Flexible Plug-in GPON MDUProducts Introduction

ZXA10 F821 is a GPON Optical Network Unit used in an FTTB/FTTO scenario. ZXA10 F821 supports VoIP, data and TDM services access. It builds a multi-tenant network center with computer technology and broadband optical network access technology, which connects various business appliances and equipments into the network to share Internet/voice connections so as to provide users with rich, diversified, personalized, convenient, comfortable, safe and effective services. Specifications * Power Consumption: 24W(16FE+16POTS); 40W(72POTS) * Power Supply: -48V DC or 110/220V AC * Dimension (W x H x D): 482.6mm x 43.6mm x 255mm * Weight: about 4.5kg * Working Temperature: -25C~55C * Working Humidity: 5%~95% Interface Function Optical port (line terminal): • ½ * GPON interface (SC/UPC) • User network interface: - Three slots mix plug in line card - 1* 10/100/1000Base-T in main control card - 8/16 /24* POTS (VoIP) per line card - 8 * E1/T1 per line card - 8 * 10/...

Huawei OptiX RTN 900 series IP microwave systems ODU details

Huawei OptiX RTN 900 series IP microwave systems Build faster, more-reliable radio transmission links supporting multiple services 1) Ultra-large bandwidth — Utilizing high modulation schemes, cross-polarization interference cancellation, and Ethernet frame header compression technologies; offer 2 Gbit/s capacity per channel 2) Carrier-grade reliability — Protection and redundancy at the network, link, and equipment levels; Ingress Protection (IP65) for water and dust, and 8 kA surge protection for high-availability operation in harsh environments 3) Easy maintenance — Unified NMS with Optics and Routers for seamless end-to-end networking, supports TP-Assist features for flexible and cost-effective O&M 4) Enhanced security – Support AES 128/256 air link encryption and device anti-theft functions Features as below : The ODU is the outdoor unit for the OptiX RTN 900. It converts frequencies and amplifies signals. The OptiX RTN 900 product series can...